Thursday, March 25, 2010

$20 LED "bulb" breakthrough ??



Bridgelux had a nice write-up yesterday in Green Venture Beat. The article entitled "Light bulbs are so over --- Bridgelux brings LED lights down to $20" leads us to believe that high performing, affordable LED general illumination light has arrived.

Unfortunately, the article fails to to mention that the $20 "light" is not actually a bulb.  It is only the LED "module" - that will require one of 15 approved power supplies -  that need to fit into one of the approved fixtures that will come eventually from one of 200 fixture manufacturers -  primarily targeting retail and commercial applications.

The idea that you can swap out a defective LED is novel.   But if a benefit of LED lights is that they last 30,000 - 50,000 hours  (using DOE/EPA usage standards that  translates into 45 years)  then one would wonder why you would need to replace an LED module?

http://green.venturebeat.com/2010/03/24/light-bulbs-are-so-over-bridgelux-brings-led-lights-down-to-20/

Tuesday, March 23, 2010

Consumer Reports - drawbacks with LED light bulbs

From Consumer Reports -

http://www.consumersearch.com/light-bulbs/led-light-bulbs

"Reviews say that in the long run, the extremely high cost ($50 to $100) of big screw-in LED light bulbs will pay for itself in savings on electricity. However, we were unable to find any compelling evidence that the rated life holds true for every bulb."

"Owners say they're dimmer than expected, even when used in a light fixture that takes advantage of their directional beam (usually a 60- to 100-degree angle). Quite a few owners find the light too cold and bluish. A few LED light bulbs are designed to cast light in all directions, to be used in a regular table lamp, but they don't put out enough lumens to make this realistic except for dim "atmospheric" background lighting."




Monday, March 15, 2010

"The buzz on dimmable CFL light bulb"

More and more consumers will discover that CFL bulbs are not going to be a viable solution in applications where dimming is desired.

Even CFL bulbs that are "dimmable" are:
  1. Only partial dimmable - usually they cut off once they reach 70-80% dimmed.
  2. They "cool" instead of "warm" when dimmed.  This means their color temperature moves to a blue/white light versus the orange/red shifts that we get (and expect) from an incandescent bulb
  3. Only dim once fully up to brightness - often taking up to two minutes.  
  4. Will not come back on at the pre-dimmed level once they have been turned off.  You have to start the entire process -  turn on, warm up, dim down process - each time you use the bulb
  5. Require that all bulbs on the circuit be identical (dimmable, same wattage, same manufacturer).
  6. Often cause the dimmer to buzz

From the Seattle Times:

"We have looked at around 20 different brands and although some of them get close, the science is not yet there," McLellan said. "We do hear of some success, however, usually with high-quality, brand-name bulbs and dimmer switches." Sometimes it's a matter of finding which brand of bulbs works with specific dimmer switches. You may need to change the dimmer."

Sunday, March 7, 2010

EPA CFL Cleanup Guidelines


  From the US Environmental Protection Agency

Cleanup and Disposal Guidelines for Compact Fluorescent Light Bulbs

Before Clean-up: Air Out the Room
•       Have people and pets leave the room, and don't let anyone walk through the breakage area on their way out.
•       Open a window and leave the room for 15 minutes or more.
•       Shut off the central forced-air heating/air conditioning system, if you have one.
Clean-Up Steps for Hard Surfaces
•       Carefully scoop up glass pieces and powder using stiff paper or cardboard and place them in a glass jar with metal lid (such as a canning jar) or in a sealed plastic bag.
•       Use sticky tape, such as duct tape, to pick up any remaining small glass fragments and powder.
•       Wipe the area clean with damp paper towels or disposable wet wipes. Place towels in the glass jar or plastic bag.
•       Do not use a vacuum or broom to clean up the broken bulb on hard surfaces.
Clean-up Steps for Carpeting or Rug
•       Carefully pick up glass fragments and place them in a glass jar with metal lid (such as a canning jar) or in a sealed plastic bag.
•       Use sticky tape, such as duct tape, to pick up any remaining small glass fragments and powder.
•       If vacuuming is needed after all visible materials are removed, vacuum the area where the bulb was broken.
•       Remove the vacuum bag (or empty and wipe the canister), and put the bag or vacuum debris in a sealed plastic bag.
Clean-up Steps for Clothing, Bedding and Other Soft Materials
•       If clothing or bedding materials come in direct contact with broken glass or mercury-containing powder from inside the bulb that may stick to the fabric, the clothing or bedding should be thrown away. Do not wash such clothing or bedding because mercury fragments in the clothing may contaminate the machine and/or pollute sewage.
•       If shoes come into direct contact with broken glass or mercury-containing powder from the bulb, wipe them off with damp paper towels or disposable wet wipes. Place the towels or wipes in a glass jar or plastic bag for disposal.
Disposal of Clean-up Materials
•       Wash your hands after disposing of the jars or plastic bags containing clean-up materials.
•       Check with your local or state government about disposal requirements in your specific area. Some states do not allow such trash disposal. Instead, they require that broken and unbroken mercury-containing bulbs be taken to a local recycling center.
Future Cleaning of Carpeting or Rug: Air Out the Room During and After Vacuuming
•       The next several times you vacuum, shut off the central forced-air heating/air conditioning system and open a window before vacuuming. Leave the central heating/air conditioning system shut off and the window open for at least 15 minutes after vacuuming is completed.

Wednesday, February 10, 2010

CFLs versus the Generator

Shortly, we will be talking more about ESL technology and the concept of ESL’s "high power factor". Power factor is a measurement of how efficient a device is to "the grid". CFL bulbs are quite energy efficient in regards to reduction in wattage, however, most CFL bulbs are very inefficient in the way they utilize power coming from the electric utility. Most CFL bulbs have a power factor that is .5 to .7. That means a 15W CFL will actually draw around 30 volt-amperes (VA). 1 VA equals 1 watt. The power company must provide the total load in VA not watts. This means that each CFL uses up to double its rated power in the regard to what the utility must deliver to your home. Commercial businesses have power factor included in their utility fees. Residential customers have not had to pay this yet. They will with the installation of smart meters. Also, just because you don't have to pay for this inefficiency it doesn't mean some non-renewable fuel isn't being used up to cover the voltage and current distribution losses caused by the poor power factor of CFL bulbs.

There was a nice article written by EDN News on the impact of CFLs and poor power factor.

http://www.edn.com/blog/1470000147/post/450043045.html

In the COMMENTS of this article was a very entertaining YouTube video. It is a a “non-scientific” demonstration of how 540 watts of CFL bulbs draw almost twice the power as a 575 watt incandescent theater lamp and end up choking a 850 watt generator.


www.youtube.com/watch?v=LeCqreRMzKM


Enjoy

Monday, February 1, 2010

Output of LEDs was overrated up to 300%




From;  http://www.ledguide.com/blog/2010/01/ledguide-com-sheds-light-on-led-bulbs/




LED bulbs often overrated


Independent research by the Dutch Metrology Institute has revealed that many LED bulbs do not meet the claims. After measuring the actual light output of the LED lamps, and their supposedly equivalent incandescent counterpart, it was found that the output of the LEDs was overrated up to 300%. Such exaggerated performance of LED light bulbs will lead to unsatisfied customers, and will eventually harm the reputation of solid-state lighting.

Thursday, January 28, 2010

Latest Video Update Posted - Shows ESL in Various Bulb Types

We have just posted the latest "ESL Update".  It can be viewed on the Vu1 website.

ESL Update #2

In the video, Vu1's ESL technology is shown in operating prototypes of various bulb shapes including the classic A-type (a typical lamp bulb) and also in relector bulb shapes used in the European Union.  Progress is being made in creating an ESL replacement product for the typical fluorescent tube.